Page 448 - RACCORDERIEMETALLICHE - LISTINO 2024
P. 448
446 ACCESSORI
Accessories • Zubehör • Accessoires • Accesorios
PRODUCT DESCRIPTION
SELON 616 is an anaerobic single component product suitable to seal metal threaded joints in according to din standard up to 2’
against water, compressed air, gas, gasoline, GPL, in private and industrial plants. The product cures spontaneously and rapidly when
confined in absence of air between close metal surfaces. SELON 616 complies with EN 751-1 for gas and hot water approved. Tixotropic
product whit middle mechanical strength for lock and seal threaded metal parts and smooth pairings.
APPROVED FOR GAS BY DVGW (GERMANY) EN751-1. APPROVAL NR NG 5146BSM0328
PROPERTIES OF UNCURED MATERIAL FEAUTURES OF CURED PRODUCT
NATURE: Methacrylic Anaerobic Resin HANDLING CURE TIME 10-15 minutes
COLOR: Blue BREAKAWAY TORQUE ISO-10964: 15-20 N.m
VISCOSITY 25°C: 30.000-60.000 mPa.s PREVAILING TORQUE ISO-10964: 10-15 N.m
SPECIFIC GRAVITY (g/ml): 1,07 FUNCTIONAL CURE TIME: 3-6 hours
FLASH POINT: >100°C FULL CURE TIME: 12-24 hours
PRODUCT STORAGE: Cool and dry place TEMPERATURE RANGE: -50°C +150°C
SHELF LIFE: 16 months at temperature +5 ° C to +28 ° C. MAX GAP FILL: 0,30 mm
POLIMERIZATION INFORMATIONS
Curing time depend on main factors: kind of metals and gap fill dimension.
The graph below shows the strength developed with time on some kind of metal. The different materials have been tested according to ISO
10964. The right temperature range of cure is from +20°C to +25°C. Low temperature from +5°C to +20°C increase curing time, higher
temperature reduce polymerization time.
CHEMICAL RESISTANCE
Test method ISO 10964 (tested at 22°C) 100
Breakaway torque % after immersion. 80
T °C 100 h 500 h 1000 h 60 zinc
Water/Glycol 85 110 110 105 % nal strength
Brake Fluid 22 100 100 100 40 brass stainless steel
Motor Oil 125 105 110 110 20
Acetone 22 105 100 105
0 5’ 10’ 20’ 30’ 1h 3h 6h 24h 72h
Gasoline 22 105 105 105 cure time
INSTRUCTION FOR USE
This product is not suitable for metal-plastic couplings and oxygen facilities as well as for the sealing of basic products or systems
with strong oxidizing acids. Use only on standard metal threads. Surface must be clean and free of grease. Apply product to fill com-
pletely the gap (male and female parts), assemble parts and shut completely. A bland or superficial closure may cause leaks over time.
Don’t after tightening. Before operating the system to wait 24 hours to allow complete curing time of Selon sealant. In the case of
series, locking the joint with a pipe wrench to avoid breaking the previous film in its formative stages. In case of passive surfaces and/
or low temperature a fast cure can be obtained using Selon 7300 activator. Consult the MSDS before use.
GENERAL INFORMATION
The data contained in this document are provided for information purposes but are not specific supply even if they are considered as
reliable products in our laboratories. We can not take responsibility for results obtained by others where the methods of work are not
under our direct control. It is your responsibility to verify the validity of the product characteristics in relation to its production needs
and to take all necessary measures for the protection of people and things from the situations that may occur with the implementa-
tion of the product.
1/2024