            SELON 616 is an anaerobic single component product suitable to seal metal threaded joints in according to din standard up to 2’
            against water, compressed air, gas, gasoline, GPL, in private and industrial plants. The product cures spontaneously and rapidly when
            confined in absence of air between close metal surfaces. SELON 616 complies with EN 751-1 for gas and hot water approved. Tixotropic
            product whit middle mechanical strength for lock and seal threaded metal parts and smooth pairings.
            APPROVED FOR GAS BY DVGW (GERMANY) EN751-1. APPROVAL NR NG 5146BSM0328

            PROPERTIES OF UNCURED MATERIAL                     FEAUTURES OF CURED PRODUCT
            NATURE: Methacrylic Anaerobic Resin                HANDLING CURE TIME 10-15 minutes
            COLOR: Blue                                        BREAKAWAY TORQUE ISO-10964: 15-20 N.m
            VISCOSITY 25°C: 30.000-60.000 mPa.s                PREVAILING TORQUE ISO-10964: 10-15 N.m
            SPECIFIC GRAVITY (g/ml): 1,07                      FUNCTIONAL CURE TIME: 3-6 hours
            FLASH POINT: >100°C                                FULL CURE TIME: 12-24 hours
            PRODUCT STORAGE: Cool and dry place                TEMPERATURE RANGE: -50°C +150°C
            SHELF LIFE: 16 months at temperature +5 ° C to +28 ° C.  MAX GAP FILL: 0,30 mm

            POLIMERIZATION INFORMATIONS
            Curing time depend on main factors: kind of metals and gap fill dimension.
            The graph below shows the strength developed with time on some kind of metal. The different materials have been tested according to ISO
            10964. The right temperature range of cure is from  +20°C to +25°C. Low temperature from +5°C to +20°C increase curing time, higher
            temperature reduce polymerization time.

            CHEMICAL RESISTANCE
            Test method  ISO 10964 (tested at 22°C)                100
            Breakaway torque % after immersion.                    80

                             T °C     100 h   500 h  1000 h        60                           zinc
             Water/Glycol    85       110     110    105         %  nal strength
             Brake Fluid     22       100     100    100           40         brass             stainless steel
             Motor Oil       125      105     110    110           20
             Acetone         22       105     100    105
                                                                      0  5’  10’  20’  30’  1h  3h  6h  24h  72h
             Gasoline        22       105     105    105                              cure time
            INSTRUCTION FOR USE
            This product is not suitable for metal-plastic couplings and oxygen facilities as well as for the sealing of basic products or systems
            with strong oxidizing acids. Use only on standard metal threads. Surface must be clean and free of grease. Apply product to fill com-
            pletely the gap (male and female parts), assemble parts and shut completely. A bland or superficial closure may cause leaks over time.
            Don’t  after tightening. Before operating the system to wait 24 hours to allow complete curing time of Selon sealant. In the case of
            series, locking the joint with a pipe wrench to avoid breaking the previous film in its formative stages. In case of passive surfaces and/
            or low temperature a fast cure can be obtained using Selon 7300 activator. Consult the MSDS before use.

            GENERAL INFORMATION
            The data contained in this document are provided for information purposes but are not specific supply even if they are considered as
            reliable products in our laboratories. We can not take responsibility for results obtained by others where the methods of work are not
            under our direct control. It is your responsibility to verify the validity of the product characteristics in relation to its production needs
            and to take all necessary measures for the protection of people and things from the situations that may occur with the implementa-
            tion of the product.


























                                                                  1/2024