Page 501 - RACCORDERIEMETALLICHE - LISTINO 2024
P. 501
SISTEMI DI FISSAGGIO 499
Fixing systems • Befestigungssysteme • Systèmes de fixation • Sistemas de fijaciónes
Y 20 21
252/ACV
TASSELLO IN ACCIAIO CON CONO E VITE PER
FISSAGGI PESANTI
• SCREW ANCHOR
• STAHLDÜBEL MIT SCHRAUBE
• CHEVILLE EN ACIER AVEC VIS
• ANCLAJE TORNILLO
L
V
D
CODE M mm mm mm g €
252006ACV M 6 47 M 6 x 55 12 32 50 3,42
252008ACV M 8 55 M 8 x 65 14 58 50 4,13
252010ACV M 10 65 M 10 x 80 16 96 25 7,22
252012ACV M 12 75 M 12 x 100 20 170 20 10,80
252016ACV M 16 92 M 16 x 110 24 306 10 20,21
CARICHI CONSIGLIATI IN daN – APPLICAZIONI IN CALCESTRUZZO CLASSE C20/25
RECOMMENDED LOADS IN daN - APPLICATIONS IN CONCRETE C20/25 CLASS
ANCORANTE/ANCHOR
230 420 590 750 1080
PARAMETRI D'INSTALLAZIONE / INSTALLATION PARAMETERS
FILETTO/THREAD
Interasse critico tra ancoranti (mm)
Critical distance between anchors (mm)
Distanza critica dal bordo (mm)
Critical distance from the edge (mm)
Interasse minimo tra ancoranti (mm)
Minimum distance between anchors (mm)
Distanza minima dal bordo (mm)
Minimum distance from the edge (mm)
Spessore minimo supporto (mm)
Minimum thickness support (mm)
Coppia di serraggio (Nm)
Torque (Nm)
NOTE
Il riquadro riporta i carichi ammissibili in daN in considerazione di:
• sollecitazioni applicate in qualsiasi direzione (trazione assiale, taglio, tiro inclinato)
• ancoranti installati con distanze dal bordo e distanze tra ancoranti uguali o superiori a quelle critiche; per distanze inferiori a
quelle critiche è necessario ridurre i carichi
• spessori di supporto uguali o maggiori a quelli riportati
The table shows the permissible loads in daN, in consideration of:
• stresses applied in any direction (axial tension, cutting, tilted load)
• anchors installed with edge distances and distances between equal anchors or exceeding the critical conditions; for distances
less than those criticals, it is necessary to reduce loads
• media thicknesses equal or bigger than those indicated above.
1/2024