Page 180 - AERMEC - CATALOGO PRODOTTI 2023 - DELLAFIORE
P. 180
Scarico condensa
Accessorio VEC20I VEC24I VEC30I VEC34I VEC40I VEC44I VEC50I VEC54I
DSC4 • • • • • • • •
DATI PRESTAZIONALI VEC
2 tubi
VEC20I VEC24I VEC30I VEC34I VEC40I VEC44I VEC50I VEC54I
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
L M H L M H L M H L M H L M H L M H L M H L M H
Prestazioni in riscaldamento 70 °C / 60 °C (1)
Potenza termica kW 1,87 2,54 3,10 2,07 2,50 3,42 3,03 3,64 4,31 4,31 53,18 6,14 4,21 5,21 6,29 5,41 6,68 8,07 4,76 6,34 7,16 6,06 8,08 9,18
Portata acqua utenza l/h 164 223 272 181 219 300 266 319 378 378 454 538 369 457 551 474 586 708 417 556 628 532 709 805
Perdita di carico lato utenza kPa 2 4 6 1 2 3 9 13 17 5 7 9 6 9 12 9 14 19 7 11 14 9 15 19
Prestazioni in riscaldamento 45 °C / 40 °C (2)
Potenza termica kW 0,95 1,26 1,54 1,20 1,40 1,70 1,50 1,81 2,14 2,15 2,57 3,05 2,09 2,59 3,12 2,69 3,30 4,01 2,37 3,15 3,56 3,02 4,02 4,54
Portata acqua utenza l/h 163 217 265 206 241 292 258 311 368 370 442 525 359 445 537 463 568 690 408 542 612 519 691 781
Perdita di carico lato utenza kPa 3 5 7 2 3 4 9 13 17 5 7 9 6 9 13 10 14 20 7 12 14 17 15 19
Prestazioni in raffreddamento 7 °C / 12 °C (3)
Potenza frigorifera kW 0,80 1,07 1,31 0,88 1,21 1,52 1,35 1,61 1,91 1,79 2,14 2,47 1,99 2,47 2,99 2,55 3,34 3,91 2,35 3,17 3,61 3,00 4,00 4,28
Potenza frigorifera sensibile kW 0,64 0,87 1,07 0,67 0,90 1,14 1,03 1,25 1,49 1,26 1,51 1,78 1,58 1,98 2,41 1,91 2,42 2,74 1,68 2,27 2,59 2,09 2,83 3,04
Portata acqua utenza l/h 138 184 225 151 208 261 232 277 329 308 368 425 342 425 514 439 574 673 404 545 621 516 688 736
Perdita di carico lato utenza kPa 3 4 6 1 2 3 6 11 13 5 6 8 6 9 12 11 17 22 7 12 15 17 27 30
Ventilatore
Tipo tipo Centrifugo
Motore ventilatore tipo Inverter
Numero n° 1 1 2 2 2 2 2 2
Portata aria m³/h 130 194 247 130 167 247 241 309 383 241 309 383 306 406 511 306 406 511 371 529 613 371 529 613
Potenza assorbita W 4 9 14 4 9 14 11 16 35 11 16 35 16 20 26 16 20 26 18 27 34 18 27 34
Segnale 0-10V % 48 70 90 48 70 90 58 66 90 58 66 90 54 72 90 54 72 90 56 78 90 56 78 90
Dati sonori ventilconvettori (4)
Livello di potenza sonora dB(A) 35,0 42,0 48,0 35,0 42,0 48,0 37,0 43,0 49,0 37,0 43,0 49,0 38,0 43,0 48,0 38,0 43,0 48,0 43,0 50,0 53,0 43,0 50,0 53,0
Livello di pressione sonora dB(A) 27,0 34,0 40,0 27,0 34,0 40,0 29,0 35,0 41,0 29,0 35,0 41,0 30,0 35,0 40,0 30,0 35,0 40,0 35,0 38,0 45,0 35,0 38,0 45,0
Diametro raccordi
Batteria principale Ø 1/2” 3/4” 1/2” 3/4” 3/4” 3/4” 3/4” 3/4”
Alimentazione
Alimentazione 230V~50Hz
(1) Aria ambiente 20 °C b.s.; Acqua (in/out) 70 °C/60 °C
(2) Aria ambiente 20 °C b.s.; Acqua (in/out) 45 °C/40 °C; EUROVENT
(3) Aria ambiente 27 °C b.s./19 °C b.u.; Acqua (in/out) 7 °C/12 °C; EUROVENT
(4) Aermec determina il valore della potenza sonora sulla base di misure effettuate in accordo con la normativa UNI EN 16583:15, nel rispetto della certificazione Eurovent.
DIMENSIONI GRIGLIE (ACCESSORIO OBBLIGATORIO)
DIMENSIONI
Dimensioni e pesi unità con griglia (ingombri massimi)
#
$
Taglia 20 24 30 34 40 44 50 54
Dimensioni e pesi
A . mm 283 283 283 283 283 283 283 283
"
B . mm 595 595 895 895 1195 1195 1195 1195
C . mm 595 595 595 595 595 595 595 595
Peso a vuoto . kg 16 16 21 21 25 25 25 25
Peso della griglia . kg 3,7 3,7 5,7 5,7 7,0 7,0 7,0 7,0
&
%
Dimensioni unità con griglia (ingombri per l'installazione)
Taglia 20 24 30 34 40 44 50 54
"
Dimensioni e pesi
A . mm 283 283 283 283 283 283 283 283
D . mm 574 574 574 574 574 574 574 574
E . mm 574 574 874 874 1174 1174 1174 1174
"FSNFD TJ SJTFSWB MB GBDPMUË EJ BQQPSUBSF JO RVBMTJBTJ NPNFOUP UVUUF "FSNFD 4 Q "
MF NPEJãDIF SJUFOVUF OFDFTTBSJF QFS JM NJHMJPSBNFOUP EFM QSPEPUUP 7JB 3PNB #FWJMBDRVB 73 *UBMJB
DPO FWFOUVBMF NPEJãDB EFJ SFMBUJWJ EBUJ UFDOJDJ 5FM 5FMFGBY
XXX BFSNFD DPN
178 www.aermec.com VEC-I_I_UN50_01