Page 49 - AERMEC - SPLIT SYSTEM-SISTEMI VRF - DELLAFIORE
P. 49

LPG_C




             Unità interna              LPG700C  LPG850C  LPG1000C  LPG1000C  LPG1200C  LPG1200C  LPG1400C  LPG1400C  LPG1600C
             Unità esterna              LPG700  LPG850  LPG1000  LPG1000T  LPG1200  LPG1200T  LPG1400  LPG1400T  LPG1600T
             Prestazioni in raffrescamento nominali
             Potenza frigorifera (1)  kW  7,10   8,50   10,50   10,50   12,10   12,10   13,40   13,40  14,50
             Potenza assorbita a freddo (1)  kW  2,03  2,50  3,10  3,10  3,90   3,90    4,60    4,60    1,50
             EER (2)              W/W    3,50    3,40    3,40   3,40    3,10    3,10    2,91    2,91    2,74
             Umidità asportata     l/h   2,4     2,8     3,3     3,3     3,7    3,7     3,9     3,9     4,8
             Prestazioni in raffrescamento minime e massime
             Potenza frigorifera  min / max  kW  2,40/7,60  2,90/9,00  3,20/11,00  3,20/11,00  3,60/13,10  3,60/13,10  4,00/14,20  4,00/14,20  4,80/15,00
             Potenza assorbita a freddo  min / max  kW  0,50/2,60  0,75/3,30  0,90/4,00  0,90/4,00  1,10/5,30  1,10/5,30  1,35/5,60  1,35/5,60  1,50/6,80
             Efficienza stagionale
             SEER                 W/W    6,70    6,90    6,60   6,60    6,10    6,10    6,30    6,30    6,10
             Classe efficienza energetica (3)  A++  A++  A++    A++      -       -       -       -       -
             Pdesignc              kW    7,1     8,5     10,5   10,5     -       -       -       -       -
                                  kWh/
             Consumo elettrico annuo     371     432     557     557     -       -       -       -       -
                                  annum
             Prestazioni in riscaldamento nominali
             Potenza termica (4)   kW    7,80    8,80   11,50   11,50   13,50   13,50   15,50   15,50  17,00
             Potenza assorbita a caldo (4)  kW  2,00  2,25  2,95  2,95  3,97    3,97    4,70    4,70    5,70
             COP (2)              W/W    3,90    3,90    3,90   3,90    3,40    3,40    3,30    3,30    2,98
             Prestazioni in riscaldamento minime e massime
             Potenza termica  min / max  kW  2,20/8,60  2,50/9,50  3,00/12,50  3,00/12,50  3,60/14,50  3,60/14,50  3,90/16,00  3,90/16,00  4,50/17,50
             Potenza assorbita a caldo  min / max  kW  0,50/3,50  0,75/3,30  0,90/4,00  0,90/4,00  0,10/5,30  1,10/5,30  1,35/5,60  1,35/5,60  1,50/6,80
             Efficienza stagionale (clima temperato)
             SCOP                        4,30    4,30    4,40   4,40    4,10    4,10    4,00    4,00    4,00
             Classe efficienza energetica (3)  A+  A+    A+      A+      -       -       -       -       -
             Pdesignh              kW    5,00    6,00    7,00   7,00     -       -       -       -       -
                                   kWh/
             Consumo elettrico annuo     1628    1954   2227    2227     -       -       -       -       -
                                  annum
             Dati elettrici
             Potenza nominale assorbita (5)  kW  2,8  3,3  4,7   4,4     5,3    5,3     5,6     5,6     6,8
             Corrente nominale assorbita (5)  A  14,0  15,0  21,0  7,0  23,0    9,0     25,0    11,0    12,0
             Ventilatore
             Tipo di ventilatore   Tipo                              Centrifugo inverter
             Portata d’aria           turbo/max/med/min  m /h  1100/1000/900/800 1400/1300/1100/1000 1500/1400/1200/1000 1500/1400/1200/1000 1700/1500/1300/1100 1700/1500/1300/1100 2000/1800/1600/1400 2000/1800/1600/1400 2300/2100/1900/1600
                                   3
             Pressione sonora (6) turbo/max/med/  dB(A)  39/38/36/34  47/46/42/38  43/41/39/38  43/41/39/38  48/46/43/39  48/46/43/39  50/48/45/41  50/48/45/41  52/50/48/44
             min
             Tubazioni frigorifere
             Diametro attacchi frigoriferi liquido  mm (inch)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)
             Diametro attacchi frigoriferi gas  mm (inch)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)  15,9 (5/8”)
             Diametro scarico condensa  mm  25   25      25      25      25      25     25      25      25
                                       220-240V ~   220-240V ~   220-240V ~   380-415V 3N~   220-240V ~   380-415V 3N~   220-240V ~   380-415V 3N~  380-415V 3N~
             Alimentazione
                                         50Hz   50Hz    50Hz    50Hz    50Hz    50Hz    50Hz    50Hz    50Hz
             Dimensioni            mm              840X840X240                        840X840X290
            (1)  Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
            (2)  EER/COP in accordo alla Normativa (EN 14511), dichiarati solo al fine delle detrazioni fiscali in vigore all’atto della realizzazione di questa pubblicazione.
            (3)  Dati in accordo con il regolamento delegato (UE) N.626/2011.
            (4)  Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
            (5)  La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
            (6)  Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.





















                                                            47