                                                            A


                                                     B

       Disegni dimensionali
                                                     200


        IQF
                                                                                               45 F


                     A                                                                        E

                                                                                      D
                                                                                              277       247
         B
                                                                                      47
                                                   128           C                                  22
                                                                              Modello  IQF 20  IQF 35  IQF 45  IQF 60  IQF 70
                                                                               A (mm)  1020  1240  1240  1360  1360
                                                                               B (mm)  495  495   495   495   591
                                                                               C (mm)  764  984   984   1104  1104
          200
                                                                               D (mm)  375  375   375   375   391
                                                                               E (mm)  123  123   123   123   219
                                                                               F (mm)  93   93    93    93    102
       Dati tecnici
                                                                             45 F
       Modelli                                       IQF 20       IQF 35       IQF 45       IQF 60       IQF 70
       PAVIMENTO/SOFFITTO
                     Alimentazione elettrica V/Ph/Hz  230±10V/1/50  230±10V/1/50  230±10V/1/50  230±10V/1/50  230±10V/1/50
                                                                           E
                     Potenza assorbita W               17           26           50           96          113

                                     3
                     Portata d’aria (A/M/B) m /h   400/315/190  595/470/340  790/580/410  1190/855/505  1360/1015/685
                                                               D
                     Potenza (A/M/B) kW            2,35/1,94/1,19  3,50/2,89/2,22  277  4,30/3,48/2,71  5,60/4,47/3,14  7,35/6,12/4,57
                                                                                            247
       Raffrescamento (1)  Portata d’acqua (A/M/B) m /h  0,40/0,34/0,21  0,60/0,50/0,38  0,74/0,60/0,47  0,96/0,77/0,54  1,27/1,05/0,79
                                      3
                     Perdite di carico lato acqua (A/M/B) kPa  13,3/9,98/4,59  34,1/24,63/15,39 54,2/36,22/22,78 50,7/33,38/17,73  44,1/33,7/19,41
                                                               47
                     Potenza (A/M/B) kW            2,60/2,11/1,34  3,50/2,87/2,19  4,30/3,43/2,60  6,00/4,77/3,36  8,05/6,46/4,71
                                                                                      22
      128        (2)  Portata d’acqua (A/M/B) m /h  0,45/0,37/0,23  0,61/0,48/0,38  0,75/0,60/0,45  1,04/0,83/0,59  1,39/1,12/0,82
                              C
       Riscaldamento
                                      3
                     Perdite di carico lato acqua (A/M/B) kPa  14,3/10,33/4,5  35,1/24,41/14,82 54,3/36,87/22,32 55,5/37,66/19,27 46,9/31,9/18,16
                     Potenza (A/M/B) kW            3,45/3,1/1,95  4,89/4,47/3,31  6,02/5,44/4,46  8,29/7,39/5,77  10,69/9,69/7,22
       Riscaldamento (3)  Portata d’acqua (A/M/B) m /h  0,59/0,27/0,11  0,84/0,39/0,19  1,04/0,47/0,26  1,43/0,64/0,33  1,84/0,83/0,41
                                      3
                     Perdite di carico lato acqua (A/M/B) kPa  19,06/4,46/0,97  44,14/10,4/2,97 65,75/14,99/5,07 65,31/14,46/4,49 61,11/14,08/4,05
       Livello di pressione sonora (A/M/B)  dB(A)   29/24/20     38/32/25     46/38/30     51/43/31      52/44/33
                              (4)
       Livello di potenza sonora (A/M/B)  dB(A)     43/37/29     52/45/37     59/52/43     65/58/56      64/58/49
                             (5)
       Scambiatore   Pressione massima di esercizio MPa  1,6        1,6          1,6          1,6          1,6
                     Dimensioni (lxhxp) mm        1020x495x200  1240x495x200  1240x495x200  1360x495x200  1360x591x200
       Corpo macchina
                     Peso netto kg                    16,5         19,5         25,5         28,5         32,5
                     Attacchi idraulici (pollici)     3/4”         3/4”         3/4”         3/4”         3/4”
       Connessioni
                     Tubo di scarico (diametro esterno) mm  Ø 18,5  Ø 18,5      Ø 18,5       Ø 18,5       Ø 18,5

       A: Ventilatore ad alta velocità; M: Ventilatore a media velocità; B: Ventilatore a bassa velocità.
       1) Modalità raffrescamento: temperatura aria in ingresso 27°C b.s. /19°C b.u., temperatura acqua in ingresso/uscita 7°C/12°C.
       2) Modalità riscaldamento: temperatura aria in ingresso 20°C b.s., temperatura acqua in ingresso/uscita 45/40°C.
       3) Modalità riscaldamento: temperatura aria in ingresso 20°C b.s., temperatura acqua in ingresso/portata d’acqua 50°C (stessa portata d’acqua in condizioni standard
       di raffrescamento).
       4) Suono testato in camera semianecoica secondo ISO 3744 a distanza di 1m (alle condizioni (2)).
       5) Secondo ISO 3744 (alle condizioni (2)).