Page 137 - AERMEC - CATALOGO PRODOTTI 2023 - FIDRA
P. 137
VENTILCONVETTORI
DATI PRESTAZIONALI
2 tubi
VED030 VED040 VED130 VED140 VED230 VED240 VED330 VED340
1 4 6 1 4 6 1 4 6 1 4 6 1 3 6 1 3 6 1 3 7 1 3 7
L M H L M H L M H L M H L M H L M H L M H L M H
Prestazioni in riscaldamento 70 °C / 60 °C (1)
Potenza termica kW 1,82 3,37 3,69 2,37 3,57 3,92 4,40 5,83 6,29 4,52 6,09 6,58 5,35 6,50 7,16 5,80 7,14 7,91 7,81 9,34 10,51 8,31 10,02 10,95
Portata acqua utenza l/h 160 296 323 207 313 343 386 512 552 396 534 577 469 570 628 509 626 694 685 819 921 729 878 960
Perdita di carico lato utenza kPa 3 7 9 4 10 12 13 22 26 9 16 18 27 30 37 18 26 32 9 13 16 22 28 32
Prestazioni in riscaldamento 45 °C / 40 °C (2)
Potenza termica kW 0,90 1,67 1,83 1,18 1,77 1,94 2,18 2,90 3,12 2,24 3,02 3,27 2,66 3,23 3,56 2,88 3,55 3,93 3,88 4,64 5,22 3,98 4,98 5,44
Portata acqua utenza l/h 157 291 318 204 208 338 380 504 543 390 526 568 462 561 618 501 616 683 674 807 907 718 865 945
Perdita di carico lato utenza kPa 3 8 9 5 11 13 15 24 28 10 16 19 26 29 36 18 27 32 10 14 17 13 20 23
Prestazioni in raffreddamento 7 °C / 12 °C (3)
Potenza frigorifera kW 0,97 1,41 1,56 1,10 1,68 1,84 2,05 2,74 2,91 2,24 3,00 3,22 2,55 3,07 3,33 2,86 3,57 3,93 3,62 4,35 4,90 3,92 4,72 5,26
Potenza frigorifera sensibile kW 0,73 1,07 1,18 0,79 1,19 1,29 1,41 1,89 2,01 1,58 2,14 2,30 1,96 2,38 2,61 2,16 2,65 2,92 2,74 3,26 3,63 2,89 3,50 3,89
Portata acqua utenza l/h 170 250 279 193 296 327 358 480 515 390 525 566 445 538 588 499 624 691 633 760 860 685 824 922
Perdita di carico lato utenza kPa 3 7 9 5 12 14 15 27 31 11 20 23 25 36 44 16 31 37 10 14 18 16 21 26
Ventilatore
Tipo tipo Centrifugo
Motore ventilatore tipo Asincrono
Numero n° 1 1 2 2 2 2 3 3
Portata aria m³/h 161 256 285 160 249 277 287 397 433 280 386 420 417 524 590 406 509 570 572 704 805 563 685 775
Pressione statica utile Pa 21 50 61 21 50 61 26 50 60 26 50 60 32 50 64 32 50 63 33 50 66 34 50 64
Potenza assorbita W 23 38 59 23 38 58 34 53 76 34 52 75 43 57 93 43 57 92 63 75 104 63 74 107
Collegamenti elettrici V1 V4 V6 V1 V4 V6 V1 V4 V6 V1 V4 V6 V1 V3 V6 V1 V3 V6 V1 V3 V7 V1 V3 V7
Dati sonori ventilconvettori canalizzati (4)
Livello di potenza sonora (inlet + radiated) dB(A) 44,0 52,0 54,0 44,0 52,0 54,0 47,0 53,0 55,0 47,0 53,0 55,0 49,0 54,0 57,0 49,0 54,0 57,0 49,0 55,0 58,0 49,0 55,0 58,0
Livello di potenza sonora (outlet) dB(A) 40,0 48,0 50,0 40,0 48,0 50,0 42,0 48,0 50,0 42,0 48,0 50,0 44,0 49,0 52,0 44,0 49,0 52,0 45,0 51,0 54,0 45,0 51,0 54,0
Batteria ad acqua
Contenuto acqua batteria principale l 0,7 1,0 1,1 1,5 1,5 2,1 1,8 2,3
Diametro raccordi
Batteria principale Ø 3/4”
Alimentazione
Alimentazione 230V~50Hz
(1) Aria ambiente 20 °C b.s.; Acqua (in/out) 70 °C/60 °C
(2) Aria ambiente 20 °C b.s.; Acqua (in/out) 45 °C/40 °C; EUROVENT
(3) Aria ambiente 27 °C b.s./19 °C b.u.; Acqua (in/out) 7 °C/12 °C; EUROVENT
(4) Aermec determina il valore della potenza sonora sulla base di misure effettuate in accordo con la normativa UNI EN 16583:15, nel rispetto della certificazione Eurovent.
DIMENSIONI
$ %
"
#
VED030 VED040 VED130 VED140 VED230 VED240 VED330 VED340
Dimensioni e pesi
A mm 217 217 217 217 217 217 217 217
B mm 550 550 781 781 1001 1001 1122 1122
C mm 560 560 560 560 560 560 560 560
D mm 576 576 807 807 1027 1027 1148 1148
"FSNFD TJ SJTFSWB MB GBDPMUË EJ BQQPSUBSF JO RVBMTJBTJ NPNFOUP UVUUF "FSNFD 4 Q "
MF NPEJãDIF SJUFOVUF OFDFTTBSJF QFS JM NJHMJPSBNFOUP EFM QSPEPUUP 7JB 3PNB #FWJMBDRVB 73 *UBMJB
DPO FWFOUVBMF NPEJãDB EFJ SFMBUJWJ EBUJ UFDOJDJ 5FM 5FMFGBY
XXX BFSNFD DPN
VED-030-340_I_UN50_04 www.aermec.com 135