Page 902 - AERMEC - CATALOGO PRODOTTI 2023 - FIDRA
P. 902
MVA711C MVA801C MVA901C MVA1001C MVA1121C MVA1251C MVA1401C
Prestazioni in raff rescamento nominali
Potenza frigorifera (1) kW 7,10 8,00 9,00 10,00 11,20 12,50 14,00
Prestazioni in riscaldamento nominali
Potenza termica (2) kW 8,00 9,00 10,00 11,20 12,50 14,00 16,00
Dati elettrici
Potenza nominale assorbita (3) W 60 85 85 85 115 115 115
Ventilatore
Tipo tipo Centrifugo inverter
Portata d’aria
Minima m³/h 850 900 900 900 1100 1100 1100
Media m³/h 950 1000 1000 1000 1300 1300 1300
Massima m³/h 1150 1250 1250 1250 1650 1650 1650
Potenza sonora (4)
Minima dB(A) 45,0 48,0 48,0 48,0 53,0 53,0 53,0
Media dB(A) 48,0 51,0 51,0 51,0 55,0 55,0 55,0
Massima dB(A) 51,0 53,0 53,0 53,0 57,0 57,0 57,0
Pressione sonora (5)
Minima dB(A) 31,0 34,0 34,0 34,0 39,0 39,0 39,0
Media dB(A) 34,0 37,0 37,0 37,0 41,0 41,0 41,0
Massima dB(A) 37,0 39,0 39,0 39,0 43,0 43,0 43,0
Tubazioni frigorifere
Diametro attacchi frigoriferi liquido mm (inch) 9,52 (3/8”)
Diametro attacchi frigoriferi gas mm (inch) 15,9 (5/8”)
Alimentazione
Alimentazione unità interna 220-240V ~ 50Hz
Unità interna
Diametro scarico condensa mm 25,0 25,0 25,0 25,0 25,0 25,0 25,0
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(3) La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
(4) Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744.
(5) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
MVA_CB
MVA1600CB
Prestazioni in raff rescamento nominali
Potenza frigorifera (1) kW 16,00
Prestazioni in riscaldamento nominali
Potenza termica (2) kW 17,50
Dati elettrici
Potenza nominale assorbita (3) W 130
Ventilatore
Tipo tipo Centrifugo inverter
Portata d’aria
Minima m³/h 1400
Media m³/h 1700
Massima m³/h 2100
Potenza sonora (4)
Minima dB(A) 52,0
Media dB(A) 54,0
Massima dB(A) 57,0
Pressione sonora (5)
Minima dB(A) 42,0
Media dB(A) 44,0
Massima dB(A) 47,0
Tubazioni frigorifere
Diametro attacchi frigoriferi liquido mm (inch) 9,52 (3/8”)
Diametro attacchi frigoriferi gas mm (inch) 19,05 (3/4”)
Alimentazione
Alimentazione unità interna 220-240V ~ 50Hz
Unità interna
Diametro scarico condensa mm 25,0
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(3) La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
(4) Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744.
(5) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
900 www.aermec.com MVBM_I_UN50_00