Page 59 - PANASONIC - LINEA VRF
P. 59

INDICE SISTEMI VRF                                        R410A                              SISTEMI VRF





          HP                                  50 HP    52 HP    54 HP   56 HP    58 HP    60 HP   62 HP    64 HP
                                            U-14ME2E8  U-16ME2E8  U-14ME2E8  U-16ME2E8  U-18ME2E8  U-20ME2E8  U-14ME2E8  U-16ME2E8
                                            U-16ME2E8  U-16ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-16ME2E8  U-16ME2E8
          Unità esterna
                                            U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-16ME2E8  U-16ME2E8
                                                                                                 U-16ME2E8  U-16ME2E8
                       Tensione     V       380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
          Alimentazione  Fase                  3ph      3ph     3ph      3ph      3ph     3ph      3ph      3ph
                       Frequenza    Hz         50       50       50      50       50       50      50       50
          Capacità di raffresc.     kW        140,0    145,0    151,0   156,0    162,0    168,0    174,0   180,0
          EER  1)                   W/W        3,55    3,46     3,49     3,41     3,40    3,35     3,60     3,52
          SEER   2)                            6,96    6,72     7,16     6,92     7,30    7,16     6,68     6,55
          Corrente                  A       64,40 - 61,10 -  68,50 - 65,00 -  70,00 - 66,50 -  74,00 - 70,30 -  76,90 - 73,10 -  80,10 - 76,10 -  79,80 - 75,80 -  84,60 - 80,30 -
                                                                                                   73,00
                                              58,90
                                                                                                           77,40
                                                                                 70,40
                                                                        67,80
                                                                                          73,40
                                                       62,70
                                                                64,10
          Potenza d'ingresso        kW        39,40    41,90    43,30   45,80    47,60    50,10    48,30   51,20
          Capacità di riscald.      kW        155,0    160,0    169,0   175,0    182,0    189,0    195,0   201,0
          COP  1)                   W/W        4,29    4,27     4,11     4,08     4,06    3,94     4,45     4,42
          SCOP  2)                             4,08    4,05     4,13     4,07     4,13    4,13     4,11     4,09
          Corrente                  A       59,60 - 56,60 -  61,90 - 58,80 -  67,10 - 63,80 -  70,10 - 66,60 -  73,20 - 69,50 -  77,60 - 73,70 -  73,10 - 69,50 -  76,00 - 72,20 -
                                              54,60
                                                                                                            69,6
                                                                                                   67,00
                                                                                          71,00
                                                                                 67,00
                                                                        64,20
                                                       56,70
                                                                61,50
          Potenza d'ingresso        kW        36,10    37,50    41,10   42,90    44,80    48,00    43,80   45,50
          Corrente di avviamento    A          6,00    6,00     6,00     6,00     6,00    6,00     8,00     8,00
          Pressione statica esterna (max.)  Pa  80      80       80      80       80       80      80       80
          Portata d'aria            m³/min     869      869     1042     1042    1 215    1 215    928      928
                       Modalità normale /
          Pressione sonora          dB(A)    65,5 / 62,5  65,5 / 62,5  65,0 / 62,0  65,5 / 62,5  64,5 / 61,5  65,0 / 62,0  67,0 / 64,0  67,0 / 64,0
                       silenziosa
          Potenza sonora  Modalità normale  dB(A)  86,5  86,5   86,0     86,5     85,5    86,0     88,0     88,0
          Dimensioni /    A x L x P  mm / kg  1 842 x 4 020   1 842 x 4 020   1 842 x 4 380   1 842 x 4 380   1 842 x 4 740   1 842 x 4 740   1 842 x 4 900   1 842 x 4 900
          Peso netto                        x 1 000 / 1 005  x 1 000 / 1 005  x 1 000 / 1 065  x 1 000 / 1 065  x 1 000 / 1 125  x 1 000 / 1 125  x 1 000 / 1 260  x 1 000 / 1 260
                                             3/4 (19,05) /   3/4 (19,05) /   3/4 (19,05) /   3/4 (19,05) /   3/4 (19,05) /   3/4 (19,05) /   3/4 (19,05) /   3/4 (19,05) /
                       Liquido      Pollici (mm)
                                                                                         7/8 (22,22)
                                             7/8 (22,22)
                                                                                                 7/8 (22,22)
                                                                                                          7/8 (22,22)
                                                                                7/8 (22,22)
                                                              7/8 (22,22)
                                                                       7/8 (22,22)
                                                      7/8 (22,22)
          Diametro delle                    1-1/2 (38,10) /  1-1/2 (38,10) /  1-1/2 (38,10) /  1-1/2 (38,10) /  1-1/2 (38,10) /  1-1/2 (38,10) /  1-5/8 (41,28) /  1-5/8 (41,28) /
          tubazioni  3)  Gas        Pollici (mm)
                                            1-5/8 (41,28)  1-5/8 (41,28)  1-5/8 (41,28)  1-5/8 (41,28)  1-5/8 (41,28)  1-5/8 (41,28)  1-3/4 (44,45)  1-3/4 (44,45)
                       Bilanciamento  Pollici (mm)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)
                                              26,10 /   26,10 /   27,30 /   27,30 /               33,20 /   33,20 /
          Refrigerante (R410A) / CO  Eq.  kg / T  54,4968  54,4968  57,0024  57,0024  28,50 / 59.508 28,50 / 59.508  69,3216  69,3216
                         2
          Rapporto di capacità interna/esterna   %  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)
          massimo consentito  4)
          Campo di     Raffresc. Min ~ Max  °C  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52
          funzionamento  Riscald. Min ~ Max  °C  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18
          HP                                  66 HP    68 HP    70 HP   72 HP    74 HP    76 HP   78 HP    80 HP
                                            U-10ME2E8  U-12ME2E8  U-10ME2E8  U-16ME2E8  U-16ME2E8  U-16ME2E8  U-18ME2E8  U-20ME2E8
          Unità esterna                     U-16ME2E8  U-16ME2E8  U-20ME2E8  U-16ME2E8  U-18ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8
                                            U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8
                                            U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8  U-20ME2E8
                       Tensione     V       380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
          Alimentazione  Fase                  3ph      3ph     3ph      3ph      3ph     3ph      3ph      3ph
                       Frequenza    Hz         50       50       50      50       50       50      50       50
          Capacità di raffresc.     kW        185,0    190,0    196,0   202,0    208,0    213,0    219,0   224,0
          EER  1)                   W/W        3,52    3,49     3,47     3,42     3,42    3,39     3,38     3,35
          SEER  2)                             6,92    6,91     7,09     6,86     7,03    7,01     7,18     7,16
                                            85,00 - 80,80 -  88,10 - 83,70 -  91,30 - 86,80 -  95,40 - 90,60 -  98,30 - 93,40 -   101,70 -   103,50 -   106,80 -
          Corrente                  A
                                              77,80    80,70    83,60   87,30    90,00  96,60 - 93,10  98,30 - 94,70 101,50 - 97,80
          Potenza d'ingresso        kW        52,60    54,50    56,50   59,00    60,80    62,90    64,70   66,80
          Capacità di riscald.      kW        207,0    213,0    219,0   226,0    233,0    239,0    245,0   252,0
          COP  1)                   W/W        4,16    4,18     4,05     4,14     4,12    4,03     4,03     3,94
          SCOP  2)                             4,11    4,17     4,13     4,06     4,12    4,07     4,13     4,13
                                            81,20 - 77,10 -  83,30 - 79,20 -  87,40 - 83,10 -  89,20 - 84,70 -  92,30 - 87,70 -  96,90 - 92,00 -  98,30 - 93,40 -   103,40 -
          Corrente                  A
                                              74,30    76,30    80,10   81,70    84,50    88,70    90,00  98,30 - 94,70
          Potenza d'ingresso        kW        49,70    51,00    54,10   54,60    56,50    59,30    60,80   64,00
          Corrente di avviamento    A          7,00    7,00     7,00     8,00     8,00    8,00     8,00     8,00
          Pressione statica esterna (max.)  Pa  80      80       80      80       80       80      80       80
          Portata d'aria            m³/min    1 266    1 274    1 439    1 274   1 447    1 447    1 620    1 620
          Pressione sonora  Modalità normale /   dB(A)  66,0 / 63,0  66,5 / 63,5  65,5 / 62,5  66,5 / 63,5  66,5 / 63,5  66,5 / 63,5  66,0 / 63,0  66,0 / 63,0
                       silenziosa
          Potenza sonora  Modalità normale  dB(A)  87,0  87,5   86,5     87,5     87,5    87,5     87,0     87,0
          Dimensioni /    A x L x P  mm / kg  1842 x 5210 x  1 842 x 5 620 x  1 842 x 5 570 x  1 842 x 5 620 x  1 842 x 5 980 x  1 842 x 5 980 x  1 842 x 6 340 x  1 842 x 6 340 x
          Peso netto                         1000 / 1275  1 000 / 1 335  1 000 / 1 335  1 000 / 1 380  1 000 / 1 440  1 000 / 1 440  1 000 / 1 500  1 000 / 1 500
                       Liquido      Pollici (mm)  3/4 (19,05) /   7/8 (22,22) /   7/8 (22,22) /   7/8 (22,22) /   7/8 (22,22) /   7/8 (22,22) /   7/8 (22,22) /   7/8 (22,22) /
                                                                                                  1 (25,04)
                                                                                         1 (25,04)
                                                                                1 (25,04)
                                                                        1 (25,04)
                                                               1 (25,04)
                                                      1 (25,04)
                                                                                                           1 (25,04)
                                             7/8 (22,22)
          Diametro delle
          tubazioni  3)  Gas        Pollici (mm)  1-5/8 (41,28) /  1-5/8 (41,28) /  1-5/8 (41,28) /  1-3/4 (44,45) /  1-3/4 (44,45) /  1-3/4 (44,45) /  1-3/4 (44,45) /  1-3/4 (44,45) /
                                                                                                           2 (50,80)
                                                                                         2 (50,80)
                                                                                                  2 (50,80)
                                                                                2 (50,80)
                                                     1-3/4 (44,45)
                                            1-3/4 (44,45)
                                                                        2 (50,80)
                                                              1-3/4 (44,45)
                       Bilanciamento  Pollici (mm)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)  1/4 (6,35)
                                              32,90 /   35,60 /         35,80 /   36,80 /   36,80 /
          Refrigerante (R410A) / CO  Eq.  kg / T             34,10 / 19.836                     38,00 / 79.344 38,00 / 79.344
                         2                    68,6952  74,3328          68,6952  76,8384  76,8384
          Rapporto di capacità interna/esterna   %  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)  50 ~ 130 (200)
          massimo consentito  4)
          Campo di     Raffresc. Min ~ Max  °C  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52  -10 ~ +52
          funzionamento  Riscald. Min ~ Max  °C  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18  -25 ~ +18
          1) Il calcolo di EER e COP è basato sulla norma EN14511. 2) I valori SEER / SCOP sono calcolati in base ai valori di efficienza stagionale di raffrescamento/riscaldamento degli ambienti “η” del REGOLAMENTO
          DELLA COMMISSIONE (UE) 2016/2281. SEER, SCOP = (η + Correzione) × PEF. 3) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza
          equivalente delle tubazioni supera i 90 m, aumentare le dimensioni dei tubi principali di 1 livello per i tubi del gas e i tubi del liquido). 4) Se sono soddisfatte le seguenti condizioni, l'intervallo effettivo è
          superiore al 130% e inferiore al 200%: A. Rispettare il numero limite di unità interne collegabili. B. Il limite inferiore del campo di funzionamento per la temperatura esterna di riscaldamento è limitato a -10 °C
          B.U. (standard -25 °C B.U.). C. Il funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.
          Condizioni nominali: Raffrescamento interno 27 °C B.S. / 19 °C B.U. Raffrescamento esterno 35 °C B.S. / 24 °C B.U. Riscaldamento interno 20 °C B.S. Riscaldamento esterno 7 °C B.S. / 6 °C B.U. (B.S.: Bulbo Secco; B.U.: Bulbo Umido).  59
          Le specifiche sono soggette a modifiche senza preavviso. Per informazioni dettagliate su ErP / Etichette energetiche, visitate i nostri siti web www.aircon.panasonic.eu o www.ptc.panasonic.eu.
   54   55   56   57   58   59   60   61   62   63   64