Bollitori vetrificati pensili con scambiatore fisso per produzione di acqua
calda sanitaria
Glasslined cylinder with fixed heat exchanger for sanitary hot water, wall
BSH mounting
ENERGY CAP. HEAT EXCHANGER
MODEL CODE LABEL LITRES M 2 LITRES Ø MM H MM QR MM DB MM P MM BP MM
+ 95°C
BSH-100 A3B0L38 PGP30 B 93 0.4 3 460 900 1015 400 145 470
BSH-150 A3B0L43 PGP30 C 148 0.7 4 560 950 1100 300 145 590
+ 110°C BSH-200 A3B0L47 PGP30 C 189 0.8 5 560 1170 1295 570 145 590
BSH-300 A3B0L51 PGP30 C 280 1.2 8 610 1410 1535 680 145 645
10 BAR
Qr: quota di ribaltamento / Qr: pivot measurement
12 BAR
BSH Quote connessioni (mm)
Scheda tecnica BSH Connection heights (mm)
INSTALLAZIONE VERTICALE INSTALLAZIONE ORIZZONTALE
VERTICAL MOUNTING HORIZONTAL MOUNTING
MODEL DN1 DN2 DN3 DN15 DN18 DN1 DN2 DN3 DN4 DN15
BSH-100 630 270 180 340 720 720 270 630 720 180 340 720
BSH-150 635 315 235 430 715 715 315 635 715 235 430 715
BSH-200 855 315 235 385 935 935 315 855 935 235 385 935
BSH-300 1045 365 265 510 1150 1145 365 1045 1145 265 510 1150
BSH Attacchi connessioni
BSH Connection sizes
INSTALLAZIONE VERTICALE INSTALLAZIONE ORIZZONTALE
VERTICAL MOUNTING HORIZONTAL MOUNTING
ANODE
MODEL ø x ø conn. x L DN1 DN2 DN3 DN5 DN10 DN15 DN18 DN1 DN2 DN3 DN4 DN10 DN15 DN18
BSH-100 32 x G1¼” x 150 G1” G1” G1” G1¼” G1¼” G½” G1” G1” G1” G1” G1” G1¼” G½” G1¼”
BSH-150 32 x G1¼” x 200 G1” G1” G1” G1¼” G1¼” G½” G1” G1” G1” G1” G1” G1¼” G½” G1¼”
BSH-200 32 x G1¼” x 200 G1” G1” G1” G1¼” G1¼” G½” G1” G1” G1” G1” G1” G1¼” G½” G1¼”
BSH-300 32 x G1¼” x 320 G1” G1” G1” G1¼” G1¼” G½” G1” G1” G1” G1” G1” G1¼” G½” G1¼”
34