Page 567 - AERMEC - CATALOGO PRODOTTI 2023 - FIDRA
P. 567

TBG - (U)
            Taglia                            1230  1310   2230  2270   2310  3270  3280   3310  4270   4310
            Prestazioni in raffreddamento 12 °C / 7 °C (1)

            Potenza frigorifera         kW    230,7  324,2  439,6  511,1  604,5  709,0  807,9  906,9  1011,3  1112,5
            Potenza assorbita           kW    65,3  91,2   124,4  143,9  170,1  201,3  230,6  257,3  290,2  323,2
            Corrente assorbita totale a freddo  A  105,7  150,9  206,2  236,4  276,6  331,9  392,1  427,3  477,6  537,6
            EER                        W/W    3,53  3,55   3,53  3,55   3,55  3,52   3,50  3,52  3,49   3,44
            Portata acqua utenza        l/h   39688  55753  75597  87882  103946  121900  138909  155919  173873  191260
            Perdita di carico lato utenza  kPa  37   32    32     33    38     39    39    41     39    42
            (1)  Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C
               TBG - (N)
            Taglia                            1230  1310   2230  2270   2310  3270  3280   3310  4270   4310
            Prestazioni in raffreddamento 12 °C / 7 °C (1)

            Potenza frigorifera         kW    230,7  324,2  439,6  511,1  604,5  709,0  807,9  906,9  1011,3  1112,5
            Potenza assorbita           kW    65,3  91,2   124,4  143,9  170,1  201,3  230,6  257,3  290,2  323,2
            Corrente assorbita totale a freddo  A  105,7  150,9  206,2  236,4  276,6  331,9  392,1  427,3  477,6  537,6
            EER                        W/W    3,53  3,55   3,53  3,55   3,55  3,52   3,50  3,52  3,49   3,44
                                                                                                                      ARIA-ACQUA
            Portata acqua utenza        l/h   39688  55753  75597  87882  103946  121900  138909  155919  173873  191260
            Perdita di carico lato utenza  kPa  37   32    32     33    38     39    39    41     39    42
            (1)  Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C

              INDICI ENERGETICI (REG. 2016/2281 UE)
            Taglia                            1230   1310  2230  2270   2310  3270  3280   3310  4270   4310
            SEER - 12/7 (EN14825: 2018) con ventilatori inverter (1)
                                  A,E   W/W   5,44   5,52  5,76   5,44  5,85  5,70   5,77  5,78   5,61  5,60
            SEER
                                  N,U   W/W   5,63   6,03  5,97   5,71  6,04  5,80   5,89  5,93   5,81  5,71
                                  A,E   %     214,6%  217,6%  227,5%  214,6%  231,1%  225,1%  227,6%  228,3%  221,5%  220,8%
            Effi  cienza stagionale
                                  N,U   %     222,3%  238,0%  235,9%  225,2%  238,7%  229,0%  232,5%  234,0%  229,2%  225,5%
            SEPR - (EN 14825: 2018) Alta temperatura con ventilatori inverter (2)
                                  A,E   W/W   6,34   5,98  5,99   6,54  6,35  6,60   6,05  6,07   5,98  5,97
            SEPR
                                  N,U   W/W   6,47   6,21  6,18   6,78  6,56  6,73   6,20  6,23   6,17  6,09
            (1)  Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.
            (2)  Calcolo eseguito con portata d’acqua FISSA.

              DATI ELETTRICI
            Taglia                            1230   1310  2230  2270   2310  3270  3280   3310  4270   4310
            Dati elettrici
                                  A,E    A    115,0  180,0  229,0  294,0  359,0  408,0  528,0  538,0  587,0  707,0
            Corrente massima (FLA)
                                  N,U    A    125,0  189,0  239,0  304,0  368,0  418,0  538,0  547,0  597,0  707,0
                                  A,E    A    26,0   36,0  151,0  220,0  230,0  180,0  249,0  424,0  209,0  608,0
            Corrente di spunto (LRA)
                                  N,U    A    36,0   45,0  161,0  230,0  239,0  190,0  259,0  433,0  219,0  608,0

              DATI TECNICI GENERALI
            Taglia                            1230   1310  2230  2270   2310  3270  3280   3310  4270   4310
            Compressore
            Tipo                 A,E,N,U  tipo                            Centrifugo
            Regolazione compressore  A,E,N,U  Tipo                        Inverter
            Numero               A,E,N,U  n°   1     1      2     2      2     3     3      3     3      4
            Circuiti             A,E,N,U  n°   1     1      1     2      1     2     1      1     2      2
            Refrigerante         A,E,N,U  tipo                            R1234ze
                                  A,E   kg    71,0  110,0  142,0  177,0  188,0  254,0  265,0  307,0  318,0  328,0
            Carica refrigerante (1)
                                  N,U   kg    82,0  121,0  153,0  188,0  198,0  265,0  276,0  286,0  328,0  328,0
            Scambiatore lato utenza
            Tipo                 A,E,N,U  tipo                           Fascio tubiero
            Numero               A,E,N,U  n°   1     1      1     1      1     1     1      1     1      1
            Attacchi idraulici
            Attacchi (in/out)    A,E,N,U  Tipo                           Giunti scanalati

            Diametro (in/out)    A,E,N,U  Ø    3”    4”     5”    6”    6”     6”    6”     6”    6”    6”
            Ventilatore
            Tipo                 A,E,N,U  tipo                             Assiali
            Motore ventilatore   A,E,N,U  tipo                            Inverter
                                  A,E   n°     4     6      8     10    12     14    16     18    20    22
            Numero
                                  N,U   n°     6     8      10    12    14     16    18     20    22    22
                                  A,E   m³/h  75280  112920  150560  188200  225840  263480  301120  338760  376400  414040
            Portata aria
                                  N,U   m³/h  112920  150560  188200  225840  263480  301120  338760  376400  414040  414040
            (1)  La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede.






            TBG-CO_I_UN50_03                           www.aermec.com                                          565