Page 86 - AERMEC - CATALOGO PRODOTTI 2024 - FIDRA
P. 86

VENTILCONVETTORI






                                                FCY500C    FCY550C     FCY600C     FCY650C    FCY700C     FCY750C
                 Alimentazione                                              230V~50Hz
                 (1)  Aria ambiente 20 °C b.s.; Acqua (in/out) 70 °C/60 °C
                 (2)  Aria ambiente 20 °C b.s.; Acqua (in/out) 45 °C/40 °C; EUROVENT
                 Per informazioni sui dati prestazionali relativi alle diverse configurazioni fare riferimen-
                 to al software di selezione.

                 DATI PRESTAZIONALI FCY_C E FCY_U (CONFIGURAZIONE DEI BOCCAGLI AD H) 4 TUBI
                 4 tubi
                                                FCY201C    FCY301C     FCY401C     FCY501C    FCY601C     FCY701C
                                              2   4  6   1   4   6   1   3   6  1   5   6   1   4   7   2  5   7
                                              L  M   H   L   M   H   L   M  H   L   M   H   L   M   H   L  M   H
                 Prestazioni in riscaldamento 65 °C / 55 °C (1)
                 Potenza termica          kW  1,06  1,37  1,48  1,82  2,39  2,55  2,19  2,75  2,99  2,59  3,30  3,34  3,13  3,85  4,35  4,13  4,40  4,60
                 Portata acqua utenza     l/h  93  120  130  159  210  223  192  240  262  226  290  301  274  336  381  361  385  403
                 Perdita di carico lato utenza  kPa  5  8  9  8  12  14  5  7  8  6  9  9   9   13  16  16  15  17
                 Prestazioni in raffreddamento 7 °C / 12 °C
                 Potenza frigorifera      kW  0,93  1,30  1,44  1,70  2,40  2,63  2,29  3,06  3,41  2,68  3,65  3,82  3,37  4,08  4,65  4,24  4,97  5,18
                 Potenza frigorifera sensibile  kW  0,74  1,14  1,18  1,27  1,86  2,03  1,66  2,24  2,52  1,94  2,70  2,83  2,70  3,34  3,92  3,24  3,83  4,02

                 Portata acqua utenza     l/h  160  224  248  292  413  452  394  526  586  461  628  657  580  702  800  729  855  891
                 Perdita di carico lato utenza  kPa  8  13  15  9  16  18  11  18  22  13  22  24  15  21  26  20  26  28
                 Ventilatore
                 Tipo                     tipo                               Centrifugo
                 Motore ventilatore       tipo                               Asincrono
                 Portata aria             m³/h 148  226  254  263  404  446  346  487  559  400  592  627  567  770  920  785  978  1050
                 Pressione statica utile  Pa  21  50  63  21  50  61  25  50  66  22  50  56  27  50  71  32  50  58
                 Livello di potenza sonora (inlet + radiated)  dB(A) 41,0  56,0  59,0  39,0  51,0  54,0  44,0  54,0  55,0  45,0  55,0  57,0  46,0  56,0  61,0  54,0  60,0  62,0
                 Livello di potenza sonora (outlet)  dB(A) 37,0  52,0  55,0  35,0  47,0  49,0  40,0  50,0  52,0  41,0  51,0  53,0  44,0  54,0  60,0  52,0  59,0  61,0
                 Potenza assorbita        W   28  41  74  38  55  78  53  63  102  49  80  96  66  89  118  92  117  138
                 Diametro raccordi
                 Scambiatore principale   Ø      1/2”        3/4”       3/4”        3/4”       3/4”        3/4”
                 Scambiatore secondario   Ø                                   1/2”
                 Alimentazione
                 Alimentazione                                              230V~50Hz

                 (1)  Aria ambiente 20 °C b.s.; Acqua (in/out) 65 °C/55 °C; EUROVENT
                 Per informazioni sui dati prestazionali relativi alle diverse configurazioni fare riferimen-
                 to al software di selezione.







































             84                                             www.aermec.com                              FCY_I_UN50_05
   81   82   83   84   85   86   87   88   89   90   91