Page 105 - ELBI - COMPENDIO 2022
P. 105

Degrassatori in polietilene per trattamento acque reflue
                                 Polyethylene grease traps for wastewater treatment

                  DG /

              DG-PRO                                     POPULATION   EQUIVALENT  PLACE   SETTINGS *  NOMINAL   SIZE  TOTAL   VOLUME  FAT    VOLUME  SLUDGE   VOLUME  LENGTH   LxL - Ø  HEIGHT  H tot   HEIGHT  H in   HEIGHT     H out   DN1/DN2


                                 MODEL          CODE    P.E.  NR.   IT/S  LITRI  LITRI  LITRI  MM  MM  MM   MM   MM
                                 DG 5         A5O0005    5    10-15  0.3  95   10   25   830x690  600  410  390  110
                                 DG 10        A5O0010   10    21-30  0.53  190  20  50   995x825  710  520  500  110
                                 DG 15        A5O0015   15    31-46  0.8  285  30   75   1135x945  795  605  585  110
                                 DG 20        A5O0020   20    41-62  1.07  380  40  100  1255x1040  875  685  665  110
                                 DG PRO 45    A5O0045   45   92-138  2.39  1020  90  225  1310   1380  940  910  110
                                 DG PRO 70    A5O0060   70   127-190  3.33  1335  120  300  1310  1640  1200  1170  110
                                 DG PRO 85    A5O0075   85   161-242  4.29  1745  150  375  1310  1900  1460  1430  110
                                 DG PRO 110   A5O0110   110  235-353  6.22  2255  220  550  1650  1790  1280  1250  125
                                 DG PRO 135   A5O0140   135  295-445  7.82  2750  280  700  1650  2080  1570  1540  125
                                 DG PRO 185   A5O0170   185  359-535  9.42  3535  340  850  1650  2380  1860  1830  125
                                 DG PRO 265   A5O0240   265  510 -765  13.47  5090  480  1200  2270  2120  1440  1410  160
                                 DG PRO 370   A5O0350   370  735 -1093  18.93  7135  700  1750  2270  2650  1970  1940  160

                                 * Calcolo valido solo per ristoranti; per attività come mense, ospedali, fornitura pasti ecc. vi invitiamo a contattare il nostro ufficio tecnico: aquapura@elbi.
                                 it / * Calculation valid only for restaurants; for activities such as canteens, hospitals, meal supply etc. we invite you to contact our technical department:
                                 aquapura@elbi.it



                                 DG / DG-PRO Disegni tecnici
                                 DG / DG-PRO Technical drawings


                                                          DG

















                                                        DG-PRO






























                                                                104
   100   101   102   103   104   105   106   107   108   109   110