DATI PRESTAZIONALI UNITÀ INTERNA
SPG_W
SPG200W SPG250W SPG350W SPG500W SPG700W
Prestazioni in raffrescamento nominali
Potenza frigorifera (1) kW 2,20 2,50 3,20 4,60 6,20
Umidità asportata l/h 0,6 0,6 1,4 1,8 1,8
Prestazioni in riscaldamento nominali
Potenza termica (2) kW 2,40 2,80 3,40 5,20 6,50
Unità interna
Tipo di ventilatore Tipo Centrifugo inverter
Potenza assorbita W 13 13 23 38 38
Portata d’aria
Minima m³/h 250 270 320 600 650
Media m³/h 420 390 400 700 750
Massima m³/h 470 470 520 800 950
Turbo m³/h 500 500 590 850 1100
Potenza sonora (3)
Minima dB(A) 34,0 34,0 38,0 44,0 49,0
Media dB(A) 45,0 44,0 45,0 48,0 52,0
Massima dB(A) 49,0 48,0 49,0 52,0 58,0
Turbo dB(A) 55,0 55,0 56,0 54,0 61,0
Pressione sonora (1 m) (4)
Minima dB(A) 22,0 22,0 26,0 34,0 35,0
Media dB(A) 33,0 32,0 33,0 38,0 38,0
Massima dB(A) 36,0 36,0 37,0 42,0 44,0
Turbo dB(A) 39,0 38,0 41,0 44,0 47,0
Unità interna
Diametro scarico condensa mm 16,0 16,0 16,0 16,0 16,0
Alimentazione
Alimentazione unità interna 220-240V ~ 50Hz
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(3) Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744.
(4) Pressione sonora misurata in camera semianecoica a 1 m di distanza frontale.
Potenza sonora misurata in campo libero in accordo con UNI EN ISO 3744.
CKG_FS
CKG260FS CKG360FS CKG500FS
Prestazioni in raffrescamento nominali
Potenza frigorifera (1) kW 2,70 3,50 5,20
Umidità asportata l/h 0,8 1,2 1,8
Prestazioni in riscaldamento nominali
Potenza termica (2) kW 2,90 3,80 5,33
Unità interna
Tipo di ventilatore Tipo Centrifugo inverter
Potenza assorbita W 35 40 50
Portata d’aria
Minima m³/h 280 360 410
Media m³/h 370 440 520
Massima m³/h 430 520 650
Turbo m³/h 500 600 700
Potenza sonora (3)
Minima dB(A) 38,0 39,0 47,0
Media dB(A) 44,0 46,0 51,0
Massima dB(A) 48,0 50,0 55,0
Turbo dB(A) 50,0 54,0 57,0
Pressione sonora (4)
Minima dB(A) 26,0 29,0 37,0
Media dB(A) 31,0 36,0 41,0
Massima dB(A) 36,0 40,0 45,0 SPLIT
Turbo dB(A) 39,0 44,0 47,0
Unità interna
Diametro scarico condensa mm 17,0 17,0 17,0
Alimentazione
Alimentazione unità interna 220-240V ~ 50Hz
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(3) Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744.
(4) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
Potenza sonora misurata in campo libero in accordo con UNI EN ISO 3744.
906 www.aermec.com MPG_I_UN50_07