Page 911 - AERMEC - CATALOGO PRODOTTI 2024 - FIDRA
P. 911
MPG_DH
MPG250DH MPG350DH MPG500DH MPG700DH
Prestazioni in raffrescamento nominali
Potenza frigorifera (1) kW 2,65 3,50 5,00 7,00
Umidità asportata l/h 0,8 1,4 1,8 2,5
Prestazioni in riscaldamento nominali
Potenza termica (2) kW 2,80 4,00 5,50 8,00
Unità interna
Tipo di ventilatore Tipo Centrifugo inverter
Potenza assorbita W 50 50 75 80
Pressione statica utile
Massima Pa 60 60 60 125
Portata d’aria
Minima m³/h 550 410 750 900
Media m³/h 610 480 790 1000
Massima m³/h 670 560 840 1200
Turbo m³/h 700 650 880 1500
Pressione sonora (1 m) (3)
Turbo dB(A) 41,0 39,0 41,0 45,0
Minima dB(A) 35,0 33,0 37,0 36,0
Media dB(A) 37,0 35,0 38,0 38,0
Massima dB(A) 39,0 37,0 39,0 40,0
Potenza sonora (4)
Minima dB(A) 51,0 49,0 53,0 53,0
Media dB(A) 53,0 51,0 54,0 55,0
Massima dB(A) 55,0 53,0 55,0 57,0
Turbo dB(A) 57,0 55,0 57,0 62,0
Unità interna
Diametro scarico condensa mm 26,0 26,0 26,0 26,0
Alimentazione
Alimentazione unità interna 220-240V ~ 50Hz
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(3) Pressione sonora misurata in camera semianecoica a 1 m di distanza frontale.
(4) Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744.
Potenza sonora misurata in campo libero in accordo con UNI EN ISO 3744.
SPLIT SPLIT
MPG_I_UN50_07 www.aermec.com 909