THERMOSTATIC ECOSAN ANTILEGIONELLA Ø 3/4”-2”
Miscelatori termostatici preassemblati per la disinfezione termica
TERMOSTATICI – antilegionella
Pre-assembled thermostatic mixing valves for thermic disinfection
anti-legionella
Speciali valvole ispezionabili con
rubinetto di chiusura, valvola di non
230
ritorno e filtro inox 230 V V
Gate valves inspectionables with non
Brugola di taratura
return valve and stainless steel filter
Hex screw for calibration
Interrutttore digitale programmabile
Programmable digital switch
Già tarati a circa 45°C per facilitare la
messa in funzione dell’impianto.
Already calibrated at about 45°C to facilitate the
startup of the plant.
Massima temperatura entrata 85°C,
a b c d
regolazione 20÷65°C.
3/4” 200 95 155 185 Maximum inlet temperature of 85°C, adjustment
20÷65°C.
1” 210 132 185 220
d c
1” 1/4 232 135 210 250
Cartuccia anticalcare e antiscottatura a
1” 1/2 234 183 230 282 norme UNI EN 1111.
a b 2” 260 195 253 300 Anti-scale and anti-scalding cartridge in keeping
with UNI EN 1111.
La legionella è una grave forma di polmonite che generalmente viene contratta per via respiratoria mediante inalazione (aerosol) di
minuscole gocce d’acqua contaminata. È stata identificata per la prima volta a seguito di una epidemia scoppiata durante un incontro
di ex legionari americani in un hotel di Philadelphia nel 1976. Per ogni informazione è opportuno consultare i seguenti siti internet:
Istituto Superiore della Sanità: www.iss.it - Ministero della Salute www.salute.gov.it - CDC Centro Americano prevenzione legionella:
www.cdc.com - Word Health Oranization - www.who.int
Le infezioni da legionella devono essere notificate all’autorità sanitaria e sono sottoposte a sorveglianza speciale dall’Organizzazione
Mondiale della Sanità.
The Legionnaires’ disease is a heavy pneumonia form. Generally it is catched by respiratory tracts through the inhalation of small droplets of contaminated water.
The bacteria got its name in 1976, when many people who went to a Philadelphia convention of the American Legion suffered from an outbreak of this disease,
a type of pneumonia. For all the information it is opportune visit the following web sites: Istituto Superiore della Sanità: www.iss.it – World Health Organization
www.who.int – CDC Centro Americano prevenzione legionella: www.cdc.com
The Legionnaires’ infections have to be reported to the Sanitary authority and they are submitted to a special surveillance from the World Health Organization.
Con l’interruttore digitale è possibile programmare l’orario e la durata della disinfezione alimentando l’impianto con l’acqua alla
temperatura dell’accumulo.
With the digital switch it is possible to program the time and duration of disinfection feeding the plant with water at the temperature of the boiler, bypassing
the mixer.
70°C 60°C 50°C
morte istantanea dei batteri morte in 2 minuti del 90% dei batteri morte in 2 ore del 90% dei batteri
instant death of bacteria death in 2 minutes of the 90% of the bacteria death in 2 hours of the 90% of the bacteria
26