Page 38 - AERMEC - SPLIT SYSTEM-SISTEMI VRF - DELLAFIORE
P. 38

LCG_D




             Unità interna                     LCG350D  LCG500D  LCG700D  LCG850D  LCG1000D  LCG1200D  LCG1400D
             Unità esterna                     LCG350   LCG500   LCG700    LCG850  LCG1000   LCG1200  LCG1400
             Prestazioni in raffrescamento nominali
             Potenza frigorifera (1)    kW      3,50     5,00     7,00      8,50    10,00     12,10    13,40
             Potenza assorbita a freddo (1)  kW  0,95    1,55     2,10      2,70     3,20     4,10     4,45
             EER (2)                   W/W      3,68     3,23     3,33      3,15     3,12     2,95     3,01
             Umidità asportata          l/h     0,9       1,6      2,4      3,2      2,8      1,7      3,3
             Prestazioni in raffrescamento minime e massime
             Potenza frigorifera  min / max  kW  0,90/4,00  1,60/5,50  2,40/8,00  2,40/9,00  3,20/11,00  3,60/12,80  6,00/14,20
             Potenza assorbita a freddo  min / max  kW  0,20/1,35  0,30/1,75  0,40/3,50  0,50/3,95  0,60/4,05  0,70/4,85  0,80/5,50
             Corrente assorbita a freddo  max  A  4,2     6,3      8,7      12,1     13,9     17,9     19,9
             Efficienza stagionale
             SEER                      W/W      6,10     6,10     6,80      6,10     6,10     5,80     6,10
             Classe efficienza energetica (3)   A++      A++      A++      A++       A++       -        -
             Pdesignc                   kW      3,5       5,0      7,0      8,5      10,0      -        -
             Consumo elettrico annuo  kWh/annum  200     277       357      480      571       -        -
             Prestazioni in riscaldamento nominali
             Potenza termica (4)        kW      4,00     5,50     8,00      8,80    12,00     13,50    15,50
             Potenza assorbita a caldo (4)  kW  1,05     1,45     2,25      2,55     3,40     4,10     4,60
             COP (2)                   W/W      3,81     3,79     3,56      3,45     3,53     3,29     3,37
             Prestazioni in riscaldamento minime e massime
             Potenza termica  min / max  kW    0,90/4,50  1,50/6,00  2,20/9,00  2,40/9,50  3,00/13,50  3,60/14,50  3,90/16,00
             Potenza assorbita a caldo  min / max  kW  0,20/1,35  0,30/1,75  0,45/3,50  0,50/3,95  0,60/4,05  0,70/4,85  0,80/5,50
             Efficienza stagionale (clima temperato)
             SCOP                               4,00     4,00     4,00      4,00     4,00      -        -
             Classe efficienza energetica (3)   A+       A+        A+       A+        A+       -        -
             Pdesignh                   kW      3,1      4,2       6,4      7,2      9,0       -        -
             Consumo elettrico annuo  kWh/annum  1110    1469     2238     2576      3147      -        -

             Dati elettrici
             Potenza nominale assorbita (5)  kW  1,4      1,8      3,5      4,0      4,1      4,9      5,5
             Corrente nominale assorbita (5)  A  6,0      8,0     16,0      18,0     18,5     22,0     25,0
             Ventilatore
             Tipo di ventilatore        Tipo                            Centrifugo inverter
             Portata d’aria                           turbo/max/med/min  m /h  650/600/510/450  950/880/820/700  1200/1160/1090/940  1500/1350/1130/950 1800/1520/1380/1270 2000/1730/1570/1400 2200/2000/1730/1490
                                        3
             Pressione statica utile             nominale/min/max  Pa  25/0/50  25/0/50  25/0/75  37/0/75  37/0/150  50/0/150  50/0/150
             Pressione sonora (6)              turbo/max/med/min  dB(A)  41,0/38,0/36,0/34,0 43,0/42,0/39,0/36,0 40,0/39,0/37,0/32,0 42,0/40,0/37,0/35,0 46,0/44,0/42,0/40,0 42,0/40,0/39,0/37,0 43,0/41,0/40,0/38,0
             Tubazioni frigorifere
             Diametro attacchi frigoriferi     6,35 (1/4”)  6,35 (1/4")  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)
             liquido                  mm (inch)
             Diametro attacchi frigoriferi gas  mm (inch)  9,52 (3/8”)  12,7 (1/2")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")
             Diametro scarico condensa  mm      26,0     26,0     26,0      26,0     26,0     26,0     26,0
                                              220-240V ~   220-240V ~   220-240V ~   220-240V ~   220-240V ~   220-240V ~   220-240V ~
             Alimentazione
                                                50Hz     50Hz     50Hz     50Hz      50Hz     50Hz     50Hz
             Dimensioni                 mm    700X450X200  1000X450X200  1300X450X220  1300X450X220  1000X700X300  1400X700X300  1400X700X300
            (1)  Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
            (2)  EER/COP in accordo alla Normativa (EN 14511), dichiarati solo al fine delle detrazioni fiscali in vigore all’atto della realizzazione di questa pubblicazione.
            (3)  Dati in accordo con il regolamento delegato (UE) N.626/2011.
            (4)  Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
            (5)  La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
            (6)  Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.


















                                                            36
   33   34   35   36   37   38   39   40   41   42   43