Page 38 - AERMEC - SPLIT SYSTEM-SISTEMI VRF - DELLAFIORE
P. 38
LCG_D
Unità interna LCG350D LCG500D LCG700D LCG850D LCG1000D LCG1200D LCG1400D
Unità esterna LCG350 LCG500 LCG700 LCG850 LCG1000 LCG1200 LCG1400
Prestazioni in raffrescamento nominali
Potenza frigorifera (1) kW 3,50 5,00 7,00 8,50 10,00 12,10 13,40
Potenza assorbita a freddo (1) kW 0,95 1,55 2,10 2,70 3,20 4,10 4,45
EER (2) W/W 3,68 3,23 3,33 3,15 3,12 2,95 3,01
Umidità asportata l/h 0,9 1,6 2,4 3,2 2,8 1,7 3,3
Prestazioni in raffrescamento minime e massime
Potenza frigorifera min / max kW 0,90/4,00 1,60/5,50 2,40/8,00 2,40/9,00 3,20/11,00 3,60/12,80 6,00/14,20
Potenza assorbita a freddo min / max kW 0,20/1,35 0,30/1,75 0,40/3,50 0,50/3,95 0,60/4,05 0,70/4,85 0,80/5,50
Corrente assorbita a freddo max A 4,2 6,3 8,7 12,1 13,9 17,9 19,9
Efficienza stagionale
SEER W/W 6,10 6,10 6,80 6,10 6,10 5,80 6,10
Classe efficienza energetica (3) A++ A++ A++ A++ A++ - -
Pdesignc kW 3,5 5,0 7,0 8,5 10,0 - -
Consumo elettrico annuo kWh/annum 200 277 357 480 571 - -
Prestazioni in riscaldamento nominali
Potenza termica (4) kW 4,00 5,50 8,00 8,80 12,00 13,50 15,50
Potenza assorbita a caldo (4) kW 1,05 1,45 2,25 2,55 3,40 4,10 4,60
COP (2) W/W 3,81 3,79 3,56 3,45 3,53 3,29 3,37
Prestazioni in riscaldamento minime e massime
Potenza termica min / max kW 0,90/4,50 1,50/6,00 2,20/9,00 2,40/9,50 3,00/13,50 3,60/14,50 3,90/16,00
Potenza assorbita a caldo min / max kW 0,20/1,35 0,30/1,75 0,45/3,50 0,50/3,95 0,60/4,05 0,70/4,85 0,80/5,50
Efficienza stagionale (clima temperato)
SCOP 4,00 4,00 4,00 4,00 4,00 - -
Classe efficienza energetica (3) A+ A+ A+ A+ A+ - -
Pdesignh kW 3,1 4,2 6,4 7,2 9,0 - -
Consumo elettrico annuo kWh/annum 1110 1469 2238 2576 3147 - -
Dati elettrici
Potenza nominale assorbita (5) kW 1,4 1,8 3,5 4,0 4,1 4,9 5,5
Corrente nominale assorbita (5) A 6,0 8,0 16,0 18,0 18,5 22,0 25,0
Ventilatore
Tipo di ventilatore Tipo Centrifugo inverter
Portata d’aria turbo/max/med/min m /h 650/600/510/450 950/880/820/700 1200/1160/1090/940 1500/1350/1130/950 1800/1520/1380/1270 2000/1730/1570/1400 2200/2000/1730/1490
3
Pressione statica utile nominale/min/max Pa 25/0/50 25/0/50 25/0/75 37/0/75 37/0/150 50/0/150 50/0/150
Pressione sonora (6) turbo/max/med/min dB(A) 41,0/38,0/36,0/34,0 43,0/42,0/39,0/36,0 40,0/39,0/37,0/32,0 42,0/40,0/37,0/35,0 46,0/44,0/42,0/40,0 42,0/40,0/39,0/37,0 43,0/41,0/40,0/38,0
Tubazioni frigorifere
Diametro attacchi frigoriferi 6,35 (1/4”) 6,35 (1/4") 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”)
liquido mm (inch)
Diametro attacchi frigoriferi gas mm (inch) 9,52 (3/8”) 12,7 (1/2") 15,9 (5/8") 15,9 (5/8") 15,9 (5/8") 15,9 (5/8") 15,9 (5/8")
Diametro scarico condensa mm 26,0 26,0 26,0 26,0 26,0 26,0 26,0
220-240V ~ 220-240V ~ 220-240V ~ 220-240V ~ 220-240V ~ 220-240V ~ 220-240V ~
Alimentazione
50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz
Dimensioni mm 700X450X200 1000X450X200 1300X450X220 1300X450X220 1000X700X300 1400X700X300 1400X700X300
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) EER/COP in accordo alla Normativa (EN 14511), dichiarati solo al fine delle detrazioni fiscali in vigore all’atto della realizzazione di questa pubblicazione.
(3) Dati in accordo con il regolamento delegato (UE) N.626/2011.
(4) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(5) La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
(6) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
36