LCG_C




             Unità interna             LCG700C  LCG850C  LCG1000C  LCG1000C  LCG1200C  LCG1200C  LCG1400C  LCG1400C  LCG1600C
             Unità esterna              LCG700  LCG850  LCG1000  LCG1000T  LCG1200  LCG1200T  LCG1400  LCG1400T  LCG1600T
             Prestazioni in raffrescamento nominali
             Potenza frigorifera (1)  kW  7,00   8,50   10,00   10,00   12,10   12,10   13,40   13,40  14,50
             Potenza assorbita a freddo (1)  kW  2,05  2,80  3,15  3,00  4,10   4,05    4,65    4,70    5,20
             EER (2)              W/W    3,41    3,04   3,17    3,33    2,95    2,99    2,88    2,85    2,79
             Umidità asportata     l/h   2,4     2,9     3,5     4,0     4,1    4,0     4,7     4,3     5,3
             Prestazioni in raffrescamento minime e massime
             Potenza frigorifera  min / max  kW  2,40/8,00  2,40/9,00  3,20/11,00  3,20/11,00  3,60/12,80  3,60/12,80  6,00/14,20  6,00/14,20  6,50/15,00
             Potenza assorbita a freddo  min / max  kW  0,40/3,50  0,50/3,95  0,60/4,05  0,60/4,05  0,70/4,85  0,60/5,30  0,80/5,50  0,80/5,95  0,85/5,95
             Corrente assorbita a freddo  max  A  8,8  12,7  13,8  5,0  17,5    5,9     20,8    7,2     7,6
             Efficienza stagionale
             SEER                 W/W    7,20    6,10   6,10    6,10    6,10    6,10    6,10    6,10    6,10
             Classe efficienza energetica (3)  A++  A++  A++    A++      -       -       -       -       -
             Pdesignc              kW    7,0     8,5    10,0    10,0     -       -       -       -       -
                                  kWh/
             Consumo elettrico annuo     340     472     566    553      -       -       -       -       -
                                  annum
             Prestazioni in riscaldamento nominali
             Potenza termica (4)   kW    8,00    8,80    12,00    12,00    13,50    13,50    15,50    15,50    17,00
             Potenza assorbita a caldo (4)  kW  2,20    2,65    3,55    3,40    4,20    4,15    4,35    4,45    4,80
             COP (2)              W/W    3,64    3,32   3,38    3,53    3,21    3,25    3,56    3,48    3,54
             Prestazioni in riscaldamento minime e massime
             Potenza termica  min / max  kW  2,20/9,00  2,40/9,50  3,00/13,50  3,00/13,50  3,60/14,50  3,60/14,50  3,90/16,00  3,90/16,00  4,50/17,50
             Potenza assorbita a caldo  min / max  kW  0,45/3,50  0,50/3,95  0,60/4,05  0,60/4,05  0,70/4,85  0,60/5,30  0,80/5,50  0,80/5,95  0,85/5,95
             Efficienza stagionale (clima temperato)
             SCOP                        3,9     4,0     4,0     4,0     3,8    3,8     3,6     4,0     3,8
             Classe efficienza energetica (3)  A  A+     A+      A+      -       -       -       -       -
             Pdesignh              kW    6,4     7,2     9,0     9,0     -       -       -       -       -
                                  kWh/
             Consumo elettrico annuo     2297   2616    3139    3168     -       -       -       -       -
                                  annum
             Dati elettrici
             Potenza nominale assorbita (5)  kW  3,5  4,0  4,1   4,7     4,9    5,3     5,5     6,0     6,0
             Corrente nominale assorbita (5)  A  16,0  18,0  18,5  7,0  22,0    8,0     25,0    9,0     9,0
             Ventilatore
             Tipo di ventilatore  Tipo                               Centrifugo inverter
             Portata d’aria           turbo/max/med/min  m /h  1100/1050/960/870 1400/1310/1180/1040 1500/1470/1380/1220 1500/1470/1380/1220 1800/1690/1470/1260 1800/1690/1470/1260 1900/1690/1480/1140 1900/1690/1480/1140 2000/1880/1620/1430
                                   3
             Pressione sonora (6)  dB(A)  43,0/42,0/40,0/39,0 49,0/47,0/44,0/41,0 50,0/48,0/46,0/42,0 50,0/48,0/46,0/42,0 51,0/49,0/46,0/42,0 51,0/49,0/46,0/42,0 52,0/51,0/48,0/45,0 52,0/51,0/48,0/45,0 54,0/52,0/50,0/48,0
             turbo/max/med/min
             Tubazioni frigorifere
             Diametro attacchi    mm   9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)  9,52 (3/8”)
             frigoriferi liquido  (inch)
             Diametro attacchi    mm   15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")  15,9 (5/8")
             frigoriferi gas      (inch)
             Diametro scarico condensa  mm  30,0  30,0  30,0    30,0    30,0    30,0    30,0    30,0    30,0
                                       220-240V ~   220-240V ~   220-240V ~  380-415V 3N  220-240V ~  380-415V 3N  220-240V ~  380-415V 3N  380-415V 3N
             Alimentazione
                                         50Hz   50Hz    50Hz    ~ 50Hz  50Hz   ~ 50Hz   50Hz   ~ 50Hz  ~ 50Hz
             Dimensioni           mm              840X840X240                         840X840X290
            (1)  Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
            (2)  EER/COP in accordo alla Normativa (EN 14511), dichiarati solo al fine delle detrazioni fiscali in vigore all’atto della realizzazione di questa pubblicazione.
            (3)  Dati in accordo con il regolamento delegato (UE) N.626/2011.
            (4)  Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
            (5)  La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
            (6)  Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.


















                                                            39